Voltage clamp experiment

In the voltage clamp experiment, the membrane current model is configured and parameterised to simulate the behaviour during a voltage clamp.

You can change the parameters of voltage clamp, such as start/end time and amplitude in the component voltage_clamp_protocol_params.

You can also modify the parameters of temperature T and boundary condition of the potential Vb, in the component parameters and boundary_conditions respectively.

The simulation experiment can be obtained by loading the corresponding SED-ML document into OpenCOR and executing the simulation.

Membrane currents during a voltage clamp

Figure [1] shows the membrane current during a voltage clamp.

[1]
originalFig11

Membrane current during voltage clamp at 4 C